Series 432 Insulated

The 432 Series doors offer a 2" (51mm) panel thickness, a nominal 24-gauge ribbed galvanized steel exterior, and a polybonded back cover. Polystyrene insulation provides an R-value of 7.35 (1.29 W/Msq) and optional isocyanurate insulation provides an R-value of 11.69 (2.06 W/Msq). A variety of options makes this door an economical solution for applications requiring a medium-duty insulated door.


Standard Features

  • Nominal Thickness - 2" (51 mm)

  • Maximum Standard Width - 20'2" (6147 mm)

  • Maximum Standard Height - 16'1" (4902 mm)

  • Exterior Steel - Nominal 24-Gauge Galvanized Steel

  • Back Cover - Polybonded Laminate (29-Gauge Galvanized Steel, HIPS-Backed Optional)

  • Insulation - Expanded Polystyrene (standard) Isocyanurate (Optional)

  • R-Value -

    • Polystyrene - 7.35 (1.29W/Msq)
    • Isocyanurate - 11.69 (2.06 W/Msq)

  • Exterior Surface- Ribbed

  • End Stiles - 16-Gauge Steel

  • Center Stiles - 16-Gauge Steel

  • Standard Mounting - Angle Mount

  • Standard Track - 2" (51 mm)

  • Standard Springs - 10,000 Cycle

  • Weatherstripping - Standard on Bottom

  • Operation - Manual Pull Rope

  • Finish - White Baked-On Polyester

  • Lock - Interior-Mounted Slide Lock


Options

  • Electric Operator or Chain Hoist
  • Full Sash Section with
    • 1/8" (3 mm) DSB
    • 1/8" (3 mm) Insulated
    • 1/8" (3 mm) and 1/4" (6 mm) Plexiglass
  • Individual Lites with 1/2" Insulated DSB
  • Industrial Brown Polyester
  • 3" (76 mm) Track
  • Bracket Mounting (Not Available on Full Vertical Door Tracks)
  • Bottom Sensing Edge
  • High-Cycle Springs in 25k, 50k, 75k, and 100k Cycles
  • Exhaust Ports
  • 5-Pin Tumbler Keyed Lock
  • Pull-Rope Auto Release

click here to learn more.


Architectural Specifications

Part 1 General

1.01 Work Included
The doors will be 432 Series as manufactured by Overhead Door Corporation.

1.02 Related Work
Opening preparation, miscellaneous or structural metal work, access panels, finish or field painting, field electrical wiring, wire, conduit, fuses and disconnect switches are in the Scope of Work of other divisions or trades.

1.03 Quality Assurance
In accordance with accepted quality assurance guidelines for motor-operated doors, both the door and electric operator (optional) shall be manufactured by a single-source producer of door systems; as by Overhead Door Corporation.

Part 2 Product

2.01 Sections
Section profile will be ribbed. Sections will be nominal, 24-gauge, roll formed galvanized steel exterior. Sections will have a nominal thickness of 2" (51 mm). Doors will have rabbeted meeting rails to form weathertight joints and provide full-width interlocking structural rigidity. Back cover will be polybonded laminate. (26-gauge galvanized steel, HIPS-backed optional)

2.02 Insulation
Insulation will be polystyrene with an R-value of 7.35 (1.29 W/Msq) (Optional isocyanurate insulation with an R-value of 11.69 or 2.06 W/Msq).

2.03 Center and End Stiles
Center and end stiles will be 16-gauge steel, formed and fastened as integral structures with the rolled sections. End stiles will be channel-shaped to 2" (51 mm) deep.

2.04 Springs
Standard springs will be 10,000 cycles. (Optional higher-cycle 25,000, 50,000, 75,000, or 100,000-cycle springs).

2.05 Hardware
Hinges and fixtures will be galvanized steel. Full-floating ball-bearing rollers will have hardened steel races. Roller sizes will be adequate for design requirements and limitations.

2.06 Track
Track is 2" (51 mm) standard (3" (76 mm) optional) angle-mounted. (Bracket-mounted track is an option, but not available on full vertical doors).

2.07 Lock
Lock will be interior-mounted slide lock. (Optional tumbler keyed lock is available.)

2.08 Weatherstrip
Bottom weatherstrip will be flexible PVC and held in place by a retainer that also provides additional reinforcement.

2.09 Finish
Finish will be factory baked-on white (Industrial brown optional) polyester coating.

2.10 Operation
Operation will be by manual pull rope. (Optional chain hoist and electric operator are available.)

Part 3 Execution

3.01 Execution
Install the doors in accordance with Overhead Door Corporation instructions and standards, using an authorized Overhead Door Corporation distributor.